KneeDaily · 膝关节运动医学文献获取 App

四股股薄肌腱移植物用于前交叉韧带重建的生物力学研究

Journal of clinical medicine · 2026-Nov-05
阅读数 12
Levaj Ivan, Bojanić Ivan, Pilipović Ana, Homolak Jan, Nizić Dinko, Šimunović Marko et al.

文章链接

分享到微信

简介

在30例尸体供体(平均42.6岁)中比较四股股薄肌腱(4GR)与四股半腱肌腱(4ST)、双股半腱-股薄肌腱(2ST2GR)移植物,4GR平均长度64.7 mm,80%超过60 mm,但直径最小(6.12 mm,2ST2GR为7.41 mm、4ST为7.98 mm)。载荷至失败测试显示,4ST最大力显著高于4GR和2ST2GR,4GR与2ST2GR间无显著差异…

英文摘要

Background/Objectives: To compare the morphological and biomechanical properties of a quadrupled gracilis (4GR) graft with two standard hamstring grafts for anterior cruciate ligament (ACL) reconstruction: a quadrupled semitendinosus (4ST) graft and a doubled semitendinosus-gracilis (2ST2GR) graft. Methods: Tendon specimens were obtained from 30 cadaveric donors (mean age, 42.6 years; range, 21-56 years). Tendon and graft dimensions were measured before biomechanical testing. Grafts underwent standardized preconditioning followed by load-to-failure testing at a displacement rate of 20 mm/min. Differences between graft types were analyzed using a generalized linear mixed-effects model, with results expressed as estimated marginal means with 95% confidence intervals (CI). Results: The mean 4GR graft length was 64.7 (95% CI, 61.6-67.8) mm, with 80% exceeding 60 mm. Graft diameter was greatest in the 4ST group, intermediate in the 2ST2GR group, and smallest in the 4GR group (7.98 [95% CI, 7.67-8.29], 7.41 [95% CI, 7.12-7.70], and 6.12 [95% CI, 5.89-6.36] mm, respectively). The 4ST graft demonstrated significantly greater maximum force than both the 4GR and 2ST2GR grafts, whereas no significant difference was observed between the 4GR and 2ST2GR grafts. In contrast, tensile strength was significantly higher in the 4GR grafts than in both the 4ST and 2ST2GR grafts. Stiffness was significantly higher in the 4ST grafts than in the 4GR grafts, whereas Young's modulus was significantly higher in the 4GR grafts than in the 4ST grafts. Conclusions: The 4GR graft provided sufficient length for all-inside ACL reconstruction in most specimens. Despite its smaller diameter and lower absolute load-bearing capacity than 4ST, the 4GR graft demonstrated higher tensile strength and Young's modulus, indicating favorable intrinsic mechanical properties. These findings may help inform graft selection in selected reconstructive procedures.

关键词

all-inside ACL reconstruction anterior cruciate ligament biomechanics gracilis tendon hamstring autograft semitendinosus tendon

链接

获取 KneeDaily

选择手机系统

iPhone前往 App Store ↗ 安卓查看下载与安装说明 →
微信内无法打开?

在微信右上角菜单选择“在浏览器打开”,或复制下面的网址到浏览器。

https://kneedaily.com/kneedaily