KneeDaily · 膝关节运动医学文献获取 App

前交叉韧带重建中胫骨骨道内外侧位置的髁间窝参考验证:一项三维影像验证研究

Archives of orthopaedic and trauma surgery · 2026-Oct-13
阅读数 0
Nam Vu Tu, Thang Vu Duc, Huy Le Duc, Phuc Luu Huu, Anh Luong Nhat, Thinh Le Duc et al.

文章链接

分享到微信

简介

这项回顾性单臂影像验证研究纳入108例接受初次全内单束ACL重建并术中行以髁间窝为参考的内外侧(NRML)验证的患者,于术前3D MRI和术后3D CT上分别测量天然胫骨足迹中心与胫骨隧道中心。内外侧方向上,天然足迹中心位于胫骨平台宽度的46.1±2.3%,隧道中心为44.8±2.0%,平均内外侧偏差为-1.01±1.52 mm(p<0.001),呈轻度内侧…

英文摘要

BACKGROUND: Non-anatomic tibial tunnel placement remains a leading contributor to anterior cruciate ligament reconstruction (ACLR) failure. Mediolateral (ML) tunnel positioning is particularly difficult intraoperatively because no consistent bony landmark defines the lateral footprint border. PURPOSE: To evaluate the accuracy of a novel intraoperative Notch-Referenced Mediolateral (NRML) verification technique by comparing the ML position of the tibial tunnel center (TTC) on postoperative 3D CT with the native tibial footprint center (TFC) on preoperative 3D MRI. METHODS: In this retrospective cross-sectional study, 108 consecutive patients underwent primary all-inside single-bundle ACLR with intraoperative NRML verification. This arthroscopic technique uses the intercondylar notch as a visual reference to verify mediolateral tibial tunnel position before definitive drilling. TFC and TTC were independently measured on preoperative 3D MRI and postoperative 3D CT using a standardized quadrant-grid protocol by two blinded observers. The primary outcome was ML deviation (tunnel - footprint). MRI-CT agreement and measurement reliability were assessed with intraclass correlation coefficients (ICC) and Bland-Altman analysis. RESULTS: The anatomical TFC was located at 46.1 ± 2.3% of tibial plateau width in the ML direction, versus 44.8 ± 2.0% for the TTC. Mean ML deviation was -1.01 ± 1.52 mm (p < 0.001), a small but statistically significant medial bias; 91.7% (95% CI 84.9-95.6%) of tunnels fell within ±3 mm of the native footprint. MRI-CT agreement was good (ICC 0.81-0.85), and inter/intraobserver reliability was good to excellent (ICC 0.78-0.89). No significant associations were found between ML deviation and sex, injury chronicity, graft diameter, or plateau size. CONCLUSION: In this single-arm cohort,NRML verification is a simple, equipment-free technique that placed the tibial tunnel within ~1 mm of the native ML footprint, with high measurement reliability. Prospective comparative and outcome studies are needed to confirm its clinical value. LEVEL OF EVIDENCE: IV.

关键词

Anterior cruciate ligament reconstruction Mediolateral position Notch referenced technique Three-dimensional imaging Tibial tunnel

链接

获取 KneeDaily

选择手机系统

iPhone前往 App Store ↗ 安卓查看下载与安装说明 →
微信内无法打开?

在微信右上角菜单选择“在浏览器打开”,或复制下面的网址到浏览器。

https://kneedaily.com/kneedaily