KneeDaily · 膝关节运动医学文献获取 App

术中手法抗阻与直接关节内可视化操作在前交叉韧带重建中的应用:一项回顾性队列研究

The American journal of sports medicine · 2026-Apr-14
阅读数 0
Cantrell W Alexander, Hale Martina E, Scariano Gabrielle, O'Toole Riley A, Serna Alfred, Scarcella Michael et al.

简介

本研究回顾性分析了922例ACL重建病例,旨在评估术中使用手动阻力测试联合直接关节内观察(不使用透视)来确认股骨端悬吊纽扣固定位置的有效性,并比较固定环与可调环纽扣的错位率。所有手术均由三位资深运动医学医生完成,均采用上述方法验证纽扣位置。术后X线片评估显示,所有患者(100%)的纽扣均成功翻转固定,但其中36例(3.9%)出现纽扣错位(定义为纽扣中心距股骨…

英文摘要

BACKGROUND: The use of femoral suspensory fixation devices is a popular technique in anterior cruciate ligament reconstruction (ACLR), but there is no consensus on the best intraoperative method for confirming proper button deployment. Recent literature suggests that manual resistance alone is at a high risk of causing button malpositioning or floating without utilizing intraoperative fluoroscopic imaging. PURPOSE: To investigate the incidence of femoral suspensory button malpositioning in patients undergoing ACLR when intraoperative manual resistance and direct intra-articular visualization maneuvers without imaging are used to confirm fixation as well as to compare the rates of button malpositioning between fixed- and adjustable-loop fixation devices. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: All patients who underwent ACLR by 3 board-certified, sports medicine fellowship-trained orthopaedic surgeons at a single institution were included. All 3 surgeons used intraoperative manual resistance and direct intra-articular visualization maneuvers to verify button device positioning. Patients were identified using prospectively collected administrative data from an institutional orthopaedic database. Patients were excluded if they did not have suspensory fixation devices used for reconstruction or if they lacked postoperative radiographs. Improper device deployment was defined as a button that was not flipped on radiography; malpositioned buttons were defined as those whose centers measured >2 mm from the femoral cortex. RESULTS: A total of 922 patients met inclusion criteria for this study. All 922 patients (100.0%) had properly deployed button devices, and 36 patients (3.9%) had malpositioned buttons. There was no difference in the rates of button malpositioning between fixed- and adjustable-loop button devices. Neither ACLR type (primary vs revision) nor graft type correlated with button malpositioning. CONCLUSION: Intraoperative manual resistance and direct intra-articular visualization maneuvers were an effective method for properly deploying suspensory button devices during ACLR. The low rates of improper deployment and malpositioning with these maneuvers do not warrant the use of intraoperative fluoroscopic imaging, resulting in safer, faster, and more cost-effective surgical procedures for patients.

关键词

anterior cruciate ligament reconstruction femoral button deployment fluoroscopic imaging suspensory fixation

链接

获取 KneeDaily

选择手机系统

iPhone前往 App Store ↗ 安卓查看下载与安装说明 →
微信内无法打开?

在微信右上角菜单选择“在浏览器打开”,或复制下面的网址到浏览器。

https://kneedaily.com/kneedaily